Coordinate mapping and calibration

README · Setup · Testing

Calibration files are historical setup measurements, not portable robot settings. Recalibrate for the physical camera, observation pose, resolution, table, and center definition. Do not overwrite committed CSV/YAML evidence while inspecting it; fit to a separate file for a new setup.

The vision model outputs image pixel coordinates:

pixel_x, pixel_y

The robot needs work-plane coordinates:

robot_x, robot_y, robot_z

The current system follows the original Sagittarius linear mapping style:

robot_x = k1 * pixel_y + b1
robot_y = k2 * pixel_x + b2

YAML format:

LinearRegression:
  k1: ...
  b1: ...
  k2: ...
  b2: ...

Recommended calibration files:

File Usage
vision_config_pick_front.yaml Front-view pick-stage calibration
vision_config_place_front.yaml Front-view place-stage calibration
vision_config_left.yaml Left-view calibration scaffold; requires site-specific validation
vision_config_right.yaml Right-view calibration scaffold; requires site-specific validation
vision_config_front.yaml Compatibility front-view config
vision_config.yaml Original compatibility entry point

The most reliable current real-robot results use:

vision_config_pick_front.yaml
vision_config_place_front.yaml

Current 3x3 calibration data:

manual_calibration_points_pick_front.csv
manual_calibration_points_place_front.csv

The calibration grid covers:

x = 0.22, 0.24, 0.26
y = -0.03, 0.00, 0.03

Do not casually reuse pick_front calibration for place_front; the robot pose, camera view, and object type can differ.

Manual calibration flow:

  1. Move the arm to a fixed observation pose.
  2. Place a calibration object on the table, such as a blue block or bucket.
  3. Detect the target with GroundingDINO.
  4. Refine the center using HSV/contour processing inside the box.
  5. Record pixel_x, pixel_y, robot_x, robot_y, score, label.
  6. Save as manual_calibration_points_*.csv.
  7. Fit vision_config_*.yaml with the manual calibration script.

Example calibration row:

pixel_x,pixel_y,robot_x,robot_y,score,label
383.7,376.9,0.22,-0.03,0.95,blue block

Calibration notes:

  • Points should cover the actual grasp/place area, not only the image center.
  • pick_front should cover where blocks usually appear.
  • place_front should cover where buckets usually appear.
  • Recalibrate if the camera position, arm observation pose, or resolution changes.
  • If the detection is correct but the robot lands in the wrong location, check calibration before blaming GroundingDINO.

Read-only fit inspection

With PyYAML installed, from the repository root:

PKG=src/sagittarius_arm_ros/sagittarius_perception/sagittarius_object_color_detector
python3 "$PKG/nodes/manual_vision_calibration.py" \
  --csv "$PKG/config/manual_calibration_points_pick_front.csv" \
  --vision-config "$PKG/config/vision_config_pick_front.yaml" --dry-run
python3 "$PKG/nodes/manual_vision_calibration.py" \
  --csv "$PKG/config/manual_calibration_points_place_front.csv" \
  --vision-config "$PKG/config/vision_config_place_front.yaml" --dry-run

--dry-run prints fitted coefficients and training-point residuals without writing YAML. Residuals are not held-out grasp or placement errors. The two CSVs contain nine points each; both cover x=0.22/0.24/0.26 m and y=-0.03/0/0.03 m. The archived log includes some mapped targets outside that grid, so it is not a workspace-wide accuracy evaluation.

New calibration session

The collection launchers can move the arm to observation poses. Use them only in a prepared operator-controlled hardware session after testing guidance. Keep the same camera resolution and HSV/box-center definition for collection and runtime. Save new measurements separately from the committed experiment files. Existing left/right YAMLs are scaffolding for further validation, not evidence of calibrated multi-view performance.

The work log records why earlier box-center calibration should be regenerated after introducing contour refinement. It does not establish that every committed calibration point was collected after that change.