Skip to content

images test: stop timing a busy machine in the drain test - #155

Merged
linyiru merged 1 commit into
mainfrom
fix/test-lingering-flake
Nov 4, 2026
Merged

linyiru merged 1 commit into
mainfrom
fix/test-lingering-flake

Conversation

@linyiru

@linyiru linyiru commented Nov 4, 2026

Copy link
Copy Markdown
Contributor

test-ec2-run.sh failed under load on a 2 s limit, which also made mutate.sh report INVALID. The limit is now far above a run's time and far below the 30 s bound and the 8 s process left behind, so only the behaviour under test can fail it.

The case gave a run 2 s against a 3 s bound, and failed under load. It now
allows far more than a run takes, and still far less than the bound or the
process left behind, so only the behaviour under test can fail it.

Signed-off-by: Yi-Ru Lin <deduce@gmail.com>

Copilot AI left a comment

Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

🟢 Approval recommended

No active review issues remain for the EC2 drain-test timing adjustments.

No open issues 🎉

What changed in this PR

This PR reduces timing sensitivity in the EC2 runner’s drain test to avoid failures under load and resulting mutate.sh INVALID results.

Changes:

  • Raises both elapsed-time limits to 6 seconds.
  • Extends the marker case’s drain bound from 3 to 30 seconds, keeping the assertion limit below that bound and the lingering process’s 8-second lifetime.
  • Updates the comment explaining the timing margins.
File Description
images/​test-ec2-run.sh Adjusts drain-test timing thresholds and documents their rationale.

Review effort: Balanced

@linyiru
linyiru merged commit 4269c69 into main Nov 4, 2026
8 checks passed
@linyiru
linyiru deleted the fix/test-lingering-flake branch November 4, 2026 20:47
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.