Child of #24.
Implement IncubationProgramV1 for EBEF's Conviron GR48 walk-in plant growth chamber. A walk-in room has materially different occupancy, safety, reservation, and environmental semantics from a reach-in chamber and must remain a distinct implementation.
Acceptance criteria:
- Confirm the installed GR48 controller, temperature, humidity, additive CO2, lighting, airflow, growth-area/height, alarms, and remote/data interfaces.
- Model the chamber as its own EBEF Asset/Zone with explicit capacity and occupancy, including its ability to contain other equipment needing environmental control.
- Support staged temperature, humidity, CO2, illumination, photoperiod, and long duration programs.
- Represent people/material access, door events, contained equipment, and reservation exclusivity without conflating the room with a portable incubator.
- Lower through a truthful reviewed controller/vendor-session format unless a supported programmable interface is verified.
- Preserve environmental traces, deviations, alarms, access events, and completion evidence.
Sources: EBEF equipment list and Conviron GR48 product page.
Child of #24.
Implement
IncubationProgramV1for EBEF's Conviron GR48 walk-in plant growth chamber. A walk-in room has materially different occupancy, safety, reservation, and environmental semantics from a reach-in chamber and must remain a distinct implementation.Acceptance criteria:
Sources: EBEF equipment list and Conviron GR48 product page.