Skip to content

One lost message stops SEM selling from a Sessy #978

Description

@traktore-org

@RienduPre has two Sessy batteries. SEM cannot sell to the grid from either, and it never says why.

The battery refuses every power setting while it is in its own "nom" mode. It has to be put in "api" mode first. Rien proved this himself: flipping the mode by hand makes the same write work straight away.

SEM does try to flip it. The flip is silently dropped, and SEM remembers it as done — so it never tries again. One lost message withdraws selling to the grid for good.

Two faults: SEM does not check that the flip landed, and it treats "I sent it" as "it worked".