Skip to content

AWG to mm2 Conversion Error #335

Description

@cjohnsonoem

Here is some simplified code to generate a cable harness using 20 AWG wire. When the output is generated, it converts 20 AWG to 0.75mm2, which is 18 AWG. Correct value should be 0.5mm2.

connectors:
  X1:
    type: JAE Electronics IL-AG5-6P-S3C1
    subtype: male
    pinlabels: [ACC, SUPPLY, IGN, SEC_SUPPLY, SEC_SIGNAL]

  X2:
    type: JAE Electronics IL-AG5-6S-S3C1
    subtype: female
    pinlabels: [ACC, SUPPLY, IGN, SEC_SUPPLY, SEC_SIGNAL]

cables:
  W1:
    gauge: 20 AWG
    show_equiv: true
    length: 0.125
    colors: [RD,BK,GN,BU,YE]
    wirecount: 5
    shield: false
  
connections:
  - # connect input to output
    - X1: [1-5]
    - W1: [1-5]
    - X2: [1-5]

image

It appears that the table in wv_helper.py is incorrect:

awg_equiv_table = {
    '0.09': '28',
    '0.14': '26',
    '0.25': '24',
    '0.34': '22',
    '0.5': '21',
    '0.75': '20',
    '1': '18',
    '1.5': '16',
    '2.5': '14',
    '4': '12',
    '6': '10',
    '10': '8',
    '16': '6',
    '25': '4',
    '35': '2',
    '50': '1',
}

Activity